testo 312-4

Productdescription

A measuring instrument for carrying out all necessary tests on gas heaters and pipes as well as water pipes. Inherently safe thanks to the use of C-Flex hoses with high impermeability. Legally compliant measurement procedure for pre-test, main test and leakage quantity measurement on gas pipes. Recording of measurement values over a defined period (e.g. 24 h) and data transfer and analysis on PC software incl. graphic presentation.

    • Gas-tightness and serviceability test by pressure drop on gas pipes according to DVGW-TRGI 2008• Load test on gas pipes according to DVGW-TRGI 2008 with the help of the high pressure probe• Checking the regulator by recording the measurement values over a defined period• Checking the gas connection pressure and gas flow pressure as well as setting the jet pressure on gas burners and boilers• Pressure tests on drinking water pipes with water using the high-pressure probe according to DIN 1988 (TRWI) as well as with air accoding to the ZVSHK information sheet• Pressure test on waste water pipes according to DIN EN 1610

Technical Data
Memory Approx. 25.000 readings
Weight Approx. 600 g
Dimensions 219 x 68 x 50 mm
Probe type Type K
Accuracy ±0.4 °C (-100 to +200 °C)±1 °C (remaining range)
Resolution 0.01 °C
Probe type High pressure probe
Meas. Range 0 to 25 bar
Accuracy ±0.5% of fsv
Resolution 10 hPa
Probe type Pressure probe
Meas. Range 0 to 200 hPa
Accuracy ±0.03 hPa (0 to +3 hPa)±1.5% of mv (+3.1 to +40 hPa)±2 hPa or ±1% of fsv (+41 to +200 hPa)
Resolution 0.01 hPa
Brochures
PDF Refference
hvac_en.pdf (0 views)
testo 312-4 differential pressure meter incl. battery and calibration protocol
  • Gas-tightness and serviceability test by pressure drop on gas pipes according to DVGW-TRGI 2008
  • Load test on gas pipes according to DVGW-TRGI 2008 with the help of the high pressure probe
  • Pressure tests on drinking water pipes with water using the high-pressure probe according to DIN 1988 (TRWI) as well as with air accoding to the ZVSHK information sheet
  • Pressure test on waste water pipes according to DIN EN 1610
Meas. range
0 to 200 hPa
Acczracy
±0.03 hPa (0 to +3 hPa) ±1.5% of mv (+3.1 to +40 hPa) ±2 hPa or ±1% of fsv (+41 to +200 hPa)
Measurement rate
auto 1 s to 24 h fast 0,04 s
Online not buyable Ordernumber: 0632 0327
Images (1)