Productdescription

For the first time, surface temperatures with smallest diameters can be measured accurately at short and long distances. The switchable optics for far-field and close focus measurement make this possible. Far-field measurements are carried out at an optical resolution of 75:1. In this way, surface temperatures can be measured accurately even at great distances from the object to be measured. At a distance of 1.2 metres from the object to be measured, the measuring spot diameter is only 16 mm. A cross laser marks the measuring spot exactly during measurement. During measurements at a short distance from the object being measured, the close focus optics has a spot diameter of only 1 mm at a distance of 70 mm. Two laser points mark the spot exactly.

  • Switchable optics for far-field measurements (75:1) and close focus (1 mm, distance 70 mm)
  • Especially bright cross laser sighting for indicating the actual measurement point
  • Integrated humidity module for measuring indoor air humidity and for determining dewpoint distance
  • Reference accuracy ± 0.75 °C with super-fast measurement technology (scanning 100 ms)
  • Backlit display (3-line), shows °C, %RH, °C td, min./max. values, alarm limit values and degree of emission
  • Optical and audible alarm when limit values are exceeded
  • Probe socket for TC probe for determining emissivity
  • Instrument memory for 90 measurement protocols
  • PC software for archiving and documenting measurement data (included in delivery)
  • Tripod fitting for online measurement via USB cable (included in delivery)
  • Measurement data documentation on site with Testo printer

Technical Data

For the first time, surface temperatures with smallest diameters can be measured accurately at short and long distances. The switchable optics for far-field and close focus measurement make this possible. Far-field measurements are carried out at an optical resolution of 75:1. In this way, surface temperatures can be measured accurately even at great distances from the object to be measured. At a distance of 1.2 metres from the object to be measured, the measuring spot diameter is only 16 mm. A cross laser marks the measuring spot exactly during measurement. During measurements at a short distance from the object being measured, the close focus optics has a spot diameter of only 1 mm at a distance of 70 mm. Two laser points mark the spot exactly.

  • Switchable optics for far-field measurements (75:1) and close focus (1 mm, distance 70 mm)
  • Especially bright cross laser sighting for indicating the actual measurement point
  • Integrated humidity module for measuring indoor air humidity and for determining dewpoint distance
  • Reference accuracy ± 0.75 °C with super-fast measurement technology (scanning 100 ms)
  • Backlit display (3-line), shows °C, %RH, °C td, min./max. values, alarm limit values and degree of emission
  • Optical and audible alarm when limit values are exceeded
  • Probe socket for TC probe for determining emissivity
  • Instrument memory for 90 measurement protocols
  • PC software for archiving and documenting measurement data (included in delivery)
  • Tripod fitting for online measurement via USB cable (included in delivery)
  • Measurement data documentation on site with Testo printer

Brochures
PDF Refference
testo 845, infrared temperature measuring instrument with cross laser sighting incl. humidity module, switchable optics for far-field and close focus measurement, PC software incl. USB data transfer cable, aluminium case, battery and calibration protocol
  • Especially bright cross laser sighting for indicating the actual measurement point
  • Integrated humidity module for measuring indoor air humidity and for determining dewpoint distance
  • Reference accuracy ± 0.75 °C with super-fast measurement technology (scanning 100 ms)
Online not buyable Ordernumber: 0563 8451
Images (3)