testo 405

testo 405 testo 405 thermal anemometer incl.duct holder and batteries Volume flow calculation up to 99,990 m3/h Easy-to-read readings thanks to swivel display Telescopic handle to 300 mm Ideal f ...

Productdescriptiontesto 405 is a thermal anemometer. It allows the measurement of air flow velocity, volume flow and temperature. testo 405 is ideal for measuring the flow in ducts or at duct openings or draughty windows. m/s and m³/h (vo ...
Technical DataStorage temperature -20 to +70 °C Operating temperature 0 to +50 °C Battery type 3 batteries Type AAA Battery life Approx. 20 h Weight 115 g Dim ...
Brochures0560_4053_en_01.pdf (0 views)
PDF Refferencerefrigeration_en.pdf (0 views)

testo 416

testo 416 testo 416 vane anemometer with telescope (max. 890 mm) incl. batteries and calibration protocol Direct display of volume flow Multi-point or timed mean calculation Max/min values Hold ...

ProductdescriptionThe compact testo 416 anemometer with permanently attached vane probe with telescopic handle (max. 890mm). Volume flow is shown directly in the display. Accurate volume flow calculation due to easy input of duct area. Timed and ...
Technical DataStorage temperature -40 to +85 °C Operating temperature -20 to +50 °C Battery type 9V block battery, 6F22 Battery life 80 h Weight 325 g Dimensi ...
Brochures0560_4160_en_01.pdf (0 views)
PDF Refferencerefrigeration_en.pdf (0 views)

testo 417

testo 417 testo 417 vane anemometer with integrated 100 mm vane incl. temperature measurement,battery and calibration protocol Temperature, flow and volume flow measurement ...

ProductdescriptionThe compact anemometer testo 417 with built-in 100 mm Ø flow / temperature vane for measuring flow velocity, volume flow and temperature. The direction of flow, i.e. blowing or sucking flow, is visible in the display. The optiona ...
Technical DataStorage temperature -40 to +85 °C Operating temperature 0 to +50 °C Battery type 9V block battery, 6F22 Battery life 50 h Weight 230 g Dimension ...
Brochures0560_4170_en_01.pdf (0 views)
PDF Refferencerefrigeration_en.pdf (0 views)

testo 425

testo 425 testo 425 compact thermal anemometer with fixed velocity probe incl. temperature measurement and telescope (max. 820 mm), battery and calibration protocol Temperature, flow and volume flow measurement Multi-point and tim ...

ProductdescriptionThe compact anemometer with permanently attached thermal flow probe inc. telescope (max. 820 mm). The volume flow is shown directly in the display. Exact calculation of volume flow due to input of duct area. Additionally, the ins ...
Technical DataStorage temperature -40 to +85 °C Operating temperature -20 to +50 °C Battery type 9V block battery, 6F22 Battery life 20 h Weight 285 g Dimensi ...
Brochures0560_4251_en_01.pdf (0 views)
PDF Refferencerefrigeration_en.pdf (0 views)

testo 435-1

testo 435-1 testo 435-1 multi-functional measurement instrument for A/C, ventilation and Indoor Air Quality, battery and calibration protocol included IAQ probe for assessment of Indoor Air Quality Vane measurement and thermal probe ...

ProductdescriptionThe measuring instrument for ambient air conditions, for assessing Indoor Air Quality and adjusting and inspecting VAC systems. testo 435-1 is an affordable introduction to measurement engineering for ambient air conditions. Th ...
Technical DataStorage temperature -30 to +70 °C Operating temperature -20 to +50 °C Battery type Alkali manganese, mignon, Type AA Battery life 200 h (typical vane measurement) ...
Brochures0560_4351_en_01.pdf (0 views)
PDF Refferencerefrigeration_en.pdf (0 views)

testo 435-2

testo 435-2 testo 435-2 multi-function measuring instrument forair conditioning, ventilation and Indoor Air Quality with data memory, PC software and USB data transfer cable, includes battery and calibration protocol Instrument memory for 10,000 read ...

ProductdescriptionThe measuring instrument for ambient air conditions, for assessment of Indoor Air Quality and adjusting and testing VAC systems, stands out on account of its efficient measurement process. Probe-controlled menus and selectable u ...
Technical DataStorage temperature -30 to +70 °C Operating temperature -20 to +50 °C Battery type Alkali manganese, mignon, Type AA Battery life 200 h (typical vane measurement) ...